Water-Saving ADA Compliant Stainless Steel Toilet with Silent Flush (PQ605)
Model Number: PQ605
External Dimensions: 700*368*500mm
Material: 304 stainless steel
Color: Primary color
Customization: OEM ODM Accecptable
The PQ605 is an ADA compliant toilet manufactured from 304 stainless steel, combining accessible-compliant dimensions with a water-saving flush and quiet operation. Engineered for hospitals, senior care facilities, and accessible public restrooms, it ships in floor-mounted or wall-mounted configurations with the documentation architects and code officials need for specification approval.
Durable
Waterproof
Eco-friendly
Fire Retardant
Pet Friendly
Easy-to-install
ADA compliance is not a label applied after manufacture — it is a set of dimensional and operational requirements that govern how the fixture is installed and used. The PQ605 is engineered to meet those requirements when installed at the correct height with appropriate clear floor space.
The bowl rim, when wall-mounted at the ADA-specified height, positions the seat between 17 and 19 inches above the finished floor — the range defined for adult accessible fixtures. The elongated bowl profile provides the user stability and clearance that round-front bowls cannot, which is why elongated configurations are the standard specification for accessible stalls. The unit accepts rear or side grab bar installations, and the concealed mounting system leaves the wall surface clear for bar placement at the mandated 33 to 36 inch height range.
For architects and specifying engineers working to the 2010 ADA Standards for Accessible Design — or to parallel standards such as the EU Accessibility Act, the UK Equality Act, and Australia’s AS 1428.1 — the PQ605 provides the dimensional foundation. The grab bar compatibility, the flush actuation force (under 5 pounds with the side-pressing button), and the bowl geometry are the three elements most scrutinized during plan review, and all three are addressed in the base design.
Water Saving Without Sacrificing Flush Performance
Water conservation is no longer optional in most commercial building codes. The PQ605’s flush system is engineered to meet the 1.28 gallons-per-flush threshold that qualifies fixtures for the U.S. EPA WaterSense program and equivalent regional water-efficiency standards in Europe, the Middle East, and Australia.
Dual Flush Capability
The flush button is available in a two-press configuration — a reduced-volume flush for liquid waste and a full-volume flush for solid waste. Dual flush operation can cut annual water consumption by 20 to 30 percent in high-traffic facilities compared to single-flush fixtures, a figure that matters directly to operating budgets in water-scarce markets across the Middle East, the Mediterranean, and the western United States.
Gravity and Siphon Options
The PQ605 supports both gravity flushing and siphon flushing methods. Gravity flush is the quieter of the two and is preferred for patient-adjacent installations. Siphon flush delivers higher velocity for waste transport and is specified where the drain line run is long or the fixture serves a high-volume public stall.
Leak-Proof One-Piece Trapway
The trapway is a one-piece molded construction with no welded seam at the joint — the single most common leak point in welded stainless traps. Eliminating that seam removes a slow-leak failure mode that, in a facility with 40 accessible stalls, can waste thousands of gallons per month without triggering any maintenance alert.
Silent Flush for Sensitive Environments
Flush noise is a documented complaint in hospitals, senior care facilities, and hotels adjacent to patient or guest rooms. A loud flush at 2 a.m. disturbs sleep, and in healthcare settings, disturbed sleep correlates directly with slower recovery.
The PQ605’s flush path is engineered to reduce the cavitation and air-entrainment noise that gravity and siphon systems generate. The water enters the bowl along a controlled channel rather than free-falling, and the trap geometry is tuned to minimize the gurgle at the end of the flush cycle. The result is a flush that registers noticeably lower on a decibel meter than a standard commercial flush-valve toilet — a difference that nursing staff and hotel guests notice without being told to listen for it.
For facilities that have received noise complaints on patient-satisfaction surveys or guest reviews, the silent flush specification is the feature that resolves them.
Projects That Demand ADA-Compliant Fixtures
Hospitals and Clinical Buildings
Patient rooms, outpatient clinics, and emergency department restrooms all require accessible fixtures. The combination of ADA-compliant dimensions, water-saving flush, and silent operation maps directly to the three priorities hospital facility teams name first: code compliance, operating-cost control, and patient comfort.
Senior Living and Assisted Care
Residential care facilities for older adults are governed by accessibility standards that mirror or exceed ADA. The elongated bowl, the accessible height, and the quiet flush are each independently cited by assisted-living developers as specification drivers.
Government and Civic Buildings
Federal, state, and municipal buildings in the United States are required to provide accessible restrooms under ADA and the Architectural Barriers Act. In Europe and the Middle East, equivalent mandates apply to public buildings under national accessibility laws. The PQ605 ships with the certification documentation these projects require for bid submission.
Airports and Transit Hubs
Accessible stalls in transportation facilities must accommodate travelers with mobility equipment, and the fixtures must survive the volume. The stainless steel construction provides the durability; the ADA-compliant geometry provides the accessibility; the water-saving flush provides the operating-cost control that airport facility managers are measured on.
Specifying for Accessibility Codes
Architects and specifying engineers need more than a product photo to put a fixture into a project manual. The PQ605 is supported with the documentation that specification requires.
Dimensioned drawings show the bowl profile, the mounting points, the spud location, and the clearances needed for grab bar placement. Flush-performance data documents the water consumption per cycle for both the reduced and full flush. Material certificates confirm the 304 (or 316) stainless steel grade. And the certification set — CE, cUPC, WaterMark, NSF/ANSI 61, ISO 9001 — covers the code references that appear in project specifications across North America, Europe, Australia, and the Middle East.
For specifiers who have had a fixture rejected at plan review because the documentation was incomplete, this is the difference between a product that gets specified and one that gets substituted out.
Surface Hygiene for Healthcare and Public Use
The non-porous 304 stainless steel surface does not absorb moisture, does not harbor bacteria in micro-cracks the way glazed ceramic can, and withstands the hospital-grade disinfectants and quaternary cleaners that patient-adjacent restrooms require daily. The polished bowl interior sheds waste and water spots in a single cleaning pass, and the seamless construction leaves no caulk line or joint where soil can accumulate.
In healthcare environments where infection control protocols govern every surface, the material choice is not aesthetic — it is a hygiene decision that the environmental services team lives with every shift.
Manufacturing and Certification Backing
Xinhe has manufactured stainless steel sanitary fixtures for institutional and commercial projects for over 30 years, with production facilities in Jiangmen, China and Ho Chi Minh City, Vietnam. The PQ605 is supplied to healthcare groups, accessibility-focused distributors, and government procurement programs across more than 80 countries, with OEM and ODM customization available for branding, packaging, and project-specific dimensions.
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
|
Product Name
|
Stainless Steel ADA Compliant Toilet
|
|
Model Number
|
PQ605
|
|
Brand Name
|
XINHE
|
|
Place of Origin
|
Guangdong, China
|
|
Application Scenario
|
Public Bathroom, Lavatory, Prison, School, Hospital, Night club
|
|
Accessories
|
Flush Pipe Component (Cistern, Grab bar, Drainer, Pipe, Flush valve, Seat and cover, Faucet)
|
|
Warranty Service
|
5 years
|
|
After-sales Service
|
Online technical support, Return and Replacement, Other
|
|
Material
|
304 stainless steel (201 and 316 stainless steel are also available)
|
|
Size
|
As the sample / Customized
|
|
Color
|
Stainless steel orginal/Black/Gun metal/Gold/Brass/Rose gold/White or as required
|
|
Flushing Method
|
Gravity Flusing / Siphon Flushing
|
|
Flush Button Type
|
Side-Pressing One-Part Form, Upper-Pressing One-Part Form, Upper-Pressing Two-End Type
|
|
Spud Location
|
Top Spud
|
|
Surface Treatment
|
Polished bowl, Brushed outer frame / Satin
|
|
Installation Type
|
Available in Floor Mounted and Wall Mounted
|
|
Customization
|
OEM ODM Accecptable
|
|
Trap Type
|
P-Trap, S-Trap
|
|
Certificates
|
CE
|
|
Project Solution Capability
|
Graphic Design, 3d Model Design, Total Solution For Projects, Cross Categories Consolidation, Others
|
|
MOQ
|
5
|
When wall-mounted, the bowl rim must position the seat between 17 and 19 inches above the finished floor, per the 2010 ADA Standards. The PQ605 is engineered to meet this range at the specified mounting height, with grab bar placement at 33 to 36 inches.
2. How much water does the water-saving flush use per cycle?
The dual flush system operates at or below the 1.28 gallons-per-flush threshold for the full flush, with a reduced-volume setting for liquid waste. Specific per-cycle volumes depend on the flush valve or cistern configuration specified for the project.
3. Is the silent flush suitable for hospital patient rooms?
Yes. The flush path is engineered to reduce cavitation and end-of-cycle gurgle noise, producing a flush that registers lower on a decibel meter than a standard commercial flush-valve unit. This is the feature most often specified for patient-adjacent and hotel-adjacent installations.
4. Does this model support grab bar installation?
Yes. The concealed mounting system leaves the wall surface clear for rear and side grab bars at the ADA-mandated height. Dimensioned drawings showing grab bar clearances are available for specification review.
5. Which accessibility standards does the toilet meet outside the United States?
The dimensional foundation supports compliance with the EU Accessibility Act, the UK Equality Act, and Australia’s AS 1428.1, among others. Project-specific compliance documentation is available for international bid packages.
6. Can the flush be sensor-activated for touchless operation?
Material Options
- Heavy-duty 304 stainless steel (316 available)
- Corrosion-resistant for harsh environments
Vandal-Proof Construction
- Seamless unibody design
- Wall or floor mounting options
Hygienic Surface Finishes
- Satin or polished finishes
- Easy to clean and disinfect
Advanced Flush Systems
- Compatible with both manual and sensor-operated systems
Patented Waste Pipe Technology
- One-piece molded trap (no welded seams)
- Eliminates leak points at weld joints
- Reduces maintenance requirements
Built to Last
- Engineered for maximum durability
- Withstands high-traffic use
Ideal for Secure Facilities
✓ Correctional institutions
✓ Schools & universities
✓ Sports arenas & gyms
✓ Transportation hubs
✓ Outdoor installations
Key Advantages
• 100% leak-proof waste system
• Reduced lifetime maintenance costs
• Vandal-resistant construction
• ADA-compliant configurations available